Troubleshooting AIS Mainframe Printing

For initial setup see: https://kb.ucla.edu/link/634

Troubleshooting:

To troubleshoot a printing problem you will need the following information:
RMT number, IP address and and the queue name of printer.

Example: RMT3695, 164.67.133.36 / North

Top 3 most common JQP-related problems and solutions:

1. The print server IP address and/or queue name don’t match the information
entered on the mainframe.

Solution: Verify with the AIS Help Desk (x66951) that your IP and queue
match what is entered in JQP.

2. The local print queue is not configured correctly
Solution: verify that Unix Print Services for Windows is installed on the print
server.

3. There is a firewall blocking traffic from the mainframe to the print server
on port 515.

Solution: configure your network firewall to allow inbound traffic
from 164.67.134.200 port 515 to your print server.

Detailed troubleshooting steps:

1. Determine if print queue is configured correctly.

Run the “lpq” command from a DOS prompt on the same network as the print server:

Usage: lpq -Sserver -Pprinter

Example:

G:\> lpq -S164.67.133.36 -PNorthWindows LPD ServerPrinter \\164.67.133.36\North

2. If the lpq command works locally, then verify that remote connections work
from the mainframe by running lpq from TSO (if necessary contact AIS for
assistance).

From TSO:

lpq (host 164.67.133.36 printer North), Windows LPD Server,, Printer ::164.67.133.36:North,,Owner Status Jobname Job-Id Size Pages Priority,,——————————————————————————————————————,,READY ,

Revision #6
Created 2007-01-05 17:26:37 UTC by Snodderly, Matthew
Updated 2011-05-10 22:33:54 UTC by Franks, Mike